TPI · Exhaust fan · Medium airflow
TPI CE 30-DV Venturi-Mounted Exhaust Fan
- 3,950 CFMon high
- 30-inchblade
- 2speeds
- 1/4 HPmotor
Amazon shows the current price, delivery and seller. As an Amazon Associate we earn from qualifying purchases.
Specs cited from Manufacturer source ↗Photos: Amazon listing ↗ · refreshed Oct 28, 2026
The TPI CE 30-DV is a 30-inch venturi-mounted, direct-drive wall exhaust fan with a two-speed, 1/4 HP, 120-volt motor and a pull-chain switch, per the listing. No airflow rating is documented, so it fits TPI replacements best.
What works
- 3,950 CFM on high from a 30-inch blade
- 2 speeds, down to 3,080 CFM on low
- 1/4 HP motor on standard 120 V power
- Pull-chain switch for speed control at the fan
- Direct drive means no belt to adjust or replace
What doesn't
- 55 lb to support when mounting
- No cord is mentioned, so plan on an electrician to wire it in
Who it's for
Good fit
- Replacing an existing TPI CE 30-DV in the same wall opening
- Contractors building a fixed 30-inch exhaust into a framed wall
- Buyers who want simple pull-chain control of two speeds
Look elsewhere if
- Sizing ventilation to a rated CFM figure
- Plug-in installs; the listing mentions no cord
- Openings that need a shutter without buying one separately
A good fit for your job? Check the current price and delivery.
See price on AmazonWhy it stands out
The CE 30-DV is TPI's 30-inch fan in a venturi mount: a direct-drive wall exhaust fan built to sit in a framed opening and push air straight out. The listing describes a 1/4 HP, 120-volt motor with two speeds and a pull-chain switch. That is a simple, easy-to-service package for a warehouse, barn or large shop wall.
The gap is performance data. No airflow, wattage or noise figure is documented for this fan. That makes the CE 30-DV a good fit when you are replacing the same TPI unit or an installer has already specified it, and a weak pick when you are choosing a fan by CFM.
What to know before you buy
- Wiring: no cord is mentioned. Budget for an electrician to hardwire it on a 120-volt circuit.
- Opening: it needs a framed wall opening sized for the 30-inch venturi, plus a clear discharge path outside.
- Shutter: the listing says it may be used with an external shutter. Without one, the opening stays open when the fan is off.
- Replacement air: a 30-inch fan needs generous intake area, such as open doors, louvers or vents on the far side of the building.
- Not published: CFM, watts, amps, noise and warranty.
How it compares
- Hessaire 30NS8V240: the same 30-inch size, listed at 6,700 CFM, with a totally enclosed IP55 motor and UL 705 certification. The pick when you need a number to size against.
- Hessaire 36NS8V370: a step up to 36 inches and a listed 9,600 CFM for larger buildings.
- iLIVING ILG8SF24V-T: smaller, but iLIVING rates it at 4,200 CFM, and it plugs in with a 6-foot cord and a built-in thermostat. Choose it to skip the electrician in a garage-sized space.
Bottom line
The CE 30-DV makes the most sense as a like-for-like TPI replacement. For a new 30-inch exhaust project, the Hessaire 30NS8V240 gives you a listed airflow figure to plan around.
Verdict
Buy the CE 30-DV if you are replacing the same TPI fan or your installer has specified it. Skip it if you need a rated CFM figure; the Hessaire 30NS8V240 is listed at 6,700 CFM in the same size.
Questions people ask
- How much air does the TPI CE 30-DV move?
- No airflow figure is documented for this listing. For a 30-inch exhaust fan with a listed rating, the Hessaire 30NS8V240 is listed at 6,700 CFM.
- Does the CE 30-DV come with a shutter?
- The listing says it may be used with an external shutter and does not describe one in the box. Budget for a shutter if the opening needs to close when the fan is off.
- Does it plug in?
- The listing does not mention a cord or plug. Plan for a qualified electrician to wire it to a 120-volt circuit.
- How is it controlled?
- The listing describes a two-speed motor with a pull-chain switch on the fan.
Before you buy
Installation and buying checks
Use these questions to verify the exact configuration. Linked facts are cited; unlisted details stay questions.
Mounting and support
What mounting method and hardware does the exact unit require?
Clearance and handling
Do the listed physical details leave enough clearance for installation, adjustment, and service?
- Blade diameter: 30 inManufacturer source ↗
- Weight: 55 lbManufacturer source ↗
Electrical match
Does the documented electrical information match the planned supply? Confirm the installed unit’s nameplate and installation instructions before connecting it.
- Voltage: 120 VManufacturer source ↗
- Current: 3.2 AManufacturer source ↗
Airflow at the job
Is the listed airflow rated at an operating point that matches the job after placement, obstructions, and system resistance are considered?
- Airflow (high): 3,950 CFMManufacturer source ↗
Location requirements
Does the site require an environmental rating or guard? Neither is listed here.
Put 3,950 CFM in context
The TPI CE 30-DV Venturi-Mounted Exhaust Fan has a listed airflow of 3,950 cubic feet per minute. The table compares this rated volume with example room volumes. It does not measure fresh-air exchange, air speed at your body, or room coverage.
| Room | Size | Nominal room volumes / hour | Nominal pass interval |
|---|---|---|---|
| One-car garage | 22 × 12 × 9 ft · 2,376 ft³ | 100× | 36 s |
| Two-car garage | 22 × 20 × 9 ft · 3,960 ft³ | 60× | 1 min |
| Workshop | 40 × 30 × 12 ft · 14,400 ft³ | 16× | 3.6 min |
| Warehouse bay | 100 × 50 × 16 ft · 80,000 ft³ | 3× | 20 min |
A circulation fan does not by itself replace indoor air. Exhaust airflow depends on a makeup-air path and system resistance. Use installed outdoor airflow for ventilation calculations.
Formula: airflow × 60 ÷ room volume. CDC explains the ventilation form of this equation; here the input is a catalog rating, so the result is a volume comparison.
Listing details
What we know about this listing
Listing data was imported on October 28, 2026. Each specification can have a different source-check date; the evidence below is the most precise source information available here.
Sources for 9 listed specifications
- Airflow (high): TPI CE-DV Series Venturi Mounted Direct Drive Exhaust Fans product page · checked Sep 23, 2026 · Standard Models / CE-DV Series table, CE 30-DV row (catalog 07986902) — “CE 30-DV: CFM High 3950, Low 3080; Blade Size 30; Speeds 2”
- Airflow (low): TPI CE-DV Series Venturi Mounted Direct Drive Exhaust Fans product page · checked Sep 23, 2026 · Standard Models / CE-DV Series table, CE 30-DV row (catalog 07986902) — “CE 30-DV: CFM High 3950, Low 3080; Blade Size 30; Speeds 2”
- Blade diameter: TPI CE-DV Series Venturi Mounted Direct Drive Exhaust Fans product page · checked Sep 23, 2026 · Standard Models / CE-DV Series table, CE 30-DV row (catalog 07986902) — “CE 30-DV: CFM High 3950, Low 3080; Blade Size 30; Speeds 2”
- Speeds: TPI CE-DV Series Venturi Mounted Direct Drive Exhaust Fans product page · checked Sep 23, 2026 · Standard Models / CE-DV Series table, CE 30-DV row (catalog 07986902) — “CE 30-DV: CFM High 3950, Low 3080; Blade Size 30; Speeds 2”
- Motor: TPI CE-DV Series Venturi Mounted Direct Drive Exhaust Fans product page · checked Sep 23, 2026 · Standard Models / CE-DV Series table, CE 30-DV row (catalog 07986902) — “CE 30-DV: Motor Rating HP 1/4; Voltage 120; Amp 3.2; RPM High 1140; Weight (lbs) 55”
- Voltage: TPI CE-DV Series Venturi Mounted Direct Drive Exhaust Fans product page · checked Sep 23, 2026 · Standard Models / CE-DV Series table, CE 30-DV row (catalog 07986902) — “CE 30-DV: Motor Rating HP 1/4; Voltage 120; Amp 3.2; RPM High 1140; Weight (lbs) 55”
- Current: TPI CE-DV Series Venturi Mounted Direct Drive Exhaust Fans product page · checked Sep 23, 2026 · Standard Models / CE-DV Series table, CE 30-DV row (catalog 07986902) — “CE 30-DV: Motor Rating HP 1/4; Voltage 120; Amp 3.2; RPM High 1140; Weight (lbs) 55”
- Max speed: TPI CE-DV Series Venturi Mounted Direct Drive Exhaust Fans product page · checked Sep 23, 2026 · Standard Models / CE-DV Series table, CE 30-DV row (catalog 07986902) — “CE 30-DV: Motor Rating HP 1/4; Voltage 120; Amp 3.2; RPM High 1140; Weight (lbs) 55”
- Weight: TPI CE-DV Series Venturi Mounted Direct Drive Exhaust Fans product page · checked Sep 23, 2026 · Standard Models / CE-DV Series table, CE 30-DV row (catalog 07986902) — “CE 30-DV: Motor Rating HP 1/4; Voltage 120; Amp 3.2; RPM High 1140; Weight (lbs) 55”
Photos illustrate the listed model. Confirm the current variant, included hardware, and finish with the seller before purchase.
Similar exhaust fans
See all →
Exhaust fan · TPI
TPI Corporation CE30-DS Direct Drive Exhaust Fan
- 3,950 CFM
- 30 in
- 1/4 HP

Exhaust fan · iLiving
iLIVING ILG8SF24V-T 24-Inch Shutter Exhaust Fan
- 4,200 CFM
- 24 in
- 1/4 HP